INDEPENDENT TEST REPORTS

STANDARD HEAVY DUTY COMMERCIAL

Capped System Test

 VIEW TEST REPORT

DOWNLOAD

  • Full Mockup Test Report – Air, Water and Structural
  • Capped Vertically and Flush Glazed Horizontally
  • Per ASTM E283-12, ASTM E331-09, E330-14 and AAMA 501.1-05
  • National Certified Testing Laboratories

Capless System Test

VIEW TEST REPORT

DOWNLOAD

  • Full Mockup Test Report – Air, Water and Structural
  • Four Sided Structurally Flush Glazed
  • Per ASTM E283-12, ASTM E331-09, E330-14 and AAMA 501.1-05
  • National Certified Testing Laboratories

SMALL MISSILE IMPACT

Capped System Test - Miami-Dade NOA

 VIEW TEST REPORT

DOWNLOAD

  • Full Mockup Test Report – Air, Water, Structural, Impact and Cycling
  • Capped Vertically and Flush Glazed Horizontally
  • Per TAS201-94, TAS202-94 and TAS203-94
  • National Certified Testing Laboratories
  • Approved For use in HVHZ – FL# 40693.4
  • Approved For use outside HVHZ

 ENGINEERING Evaluation REPORT

DOWNLOAD

Capless System Test - Miami-Dade NOA

 VIEW TEST REPORT

DOWNLOAD

  • Full Mockup Test Report – Air, Water, Structural, Impact and Cycling
  • Four Sided Structurally Flush Glazed
  • Per TAS201-94,  TAS202-94 and TAS203-94
  • National Certified Testing Laboratories
  • Approved For use in HVHZ – FL# 40693.2
  • Approved For use outside HVHZ

 ENGINEERING Evaluation REPORT

DOWNLOAD

LARGE MISSILE IMPACT

Capped System Test - Miami-Dade NOA

 VIEW TEST REPORT

DOWNLOAD

  • Full Mockup Test Report – Air, Water, Structural, Impact and Cycling
  • Capped Vertically and Flush Glazed Horizontally
  • Per TAS201-94,  TAS202-94 and TAS203-94
  • National Certified Testing Laboratories
  • Approved For use in HVHZ – FL# 40693.3
  • Approved for use outside HVHZ

 Engineering Evaluation REPORT

DOWNLOAD

Capless System Test - Miami-Dade NOA

 VIEW TEST REPORT

DOWNLOAD

  • Full Mockup Test Report – Air, Water, Structural, Impact and Cycling
  • Four Sided Structurally Flush Glazed
  • Per TAS201-94,  TAS202-94 and TAS203-94
  • National Certified Testing Laboratories
  • Approved For use in HVHZ – FL# 40693.1
  • Approved for use outside HVHZ

 ENGINEERING Evaluation REPORT

DOWNLOAD

LARGE/SMALL MISSILE IMPACT

Capped System Test - Florida Building Code

 VIEW TEST REPORT

DOWNLOAD

  • Full Mockup Test Report – Air, Water, Structural, Impact and Cycling
  • Capped Vertically and Flush Glazed Horizontally
  • Per TAS201-94,  TAS202-94 and TAS203-94
  • National Certified Testing Laboratories
  • Not Approved For use in HVHZ
  • Approved for use outside HVHZ – FL# 8735.1

 ENGINEERING Evaluation REPORT

DOWNLOAD

EZ-Lite Pre-Glazed / Pre-Assembled System

Unit Skylight System Test - Curb Mount

 VIEW TEST REPORT

DOWNLOAD

  • Full Mockup Test Report – Air, Water and Structural
  • Per AAMA/WMDA 1600/I.SS.7-2000
  • National Certified Testing Laboratories

Adhesion and Compatability Testing

Dowsil Silicone Sealant

 VIEW TEST REPORT

DOWNLOAD

  • Sample Adhesion and Compatibility Test Report
  • Follows ASTM C794 and ASTM 1087
  • Dow Corporation

THERMAL PERFORMANCE

NFRC Product Certification Authorization Report

 VIEW TEST REPORT

DOWNLOAD

  • Validation with Simulation of Various Glass Types
  • Per NFRC 100, 200 and 500
  • National Certified Testing Laboratories

AAMA Thermal Test Summary Report

 VIEW TEST REPORT

DOWNLOAD

  • Condensation Resistance Factor and U-Factor
  • Per AAMA 1503-09
  • National Certified Testing Laboratories